Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
2.
Clin. transl. oncol. (Print) ; 23(2): 229-239, feb. 2021. ilus
Artigo em Inglês | IBECS | ID: ibc-220606

RESUMO

Purpose This study sought to discern the clinical outcomes of intensity-modulated radiation therapy (IMRT) administered to the spine in patients who had undergone previous radiotherapy. Methods A total of 81 sites of 74 patients who underwent previous radiotherapy administered to the spine or peri-spine and subsequently received IMRT for the spine were analyzed in this study. The prescribed dose of 80 Gy in a biologically effective dose (BED) of α/β = 10 (BED10) was set as the planning target volume. The constraint for the spinal cord and cauda equine was D0.1 cc ≤ 100 Gy and ≤ 150 Gy of BED for re-irradiation alone and the total irradiation dose, respectively. Results The median follow-up period was 10.1 (0.9–92.1) months after re-irradiation, while the median interval from the last day of the previous radiotherapy to the time of re-irradiation was 15.6 (0.4–210.1) months. Separately, the median prescript dose of re-irradiation was 78.0 (28.0–104.9) of BED10. The median survival time in this study was 13.9 months, with 1-, 3-, and 5-year overall survival rates of 53.7%, 29.3%, and 26.6%, respectively. The 1-, 3-, and 5-year local control rates were 90.8%, 84.0%, and 84.0%, respectively. Neurotoxicity was observed in two of 72 treatments (2.8%) assessed after re-irradiation. Conclusion Re-irradiation for the spine using IMRT seems well-tolerated. Definitive re-irradiation can be a feasible treatment option in patients with the potential for a good prognosis (AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Radioterapia de Intensidade Modulada/efeitos adversos , Reirradiação/métodos , Neoplasias da Medula Espinal/radioterapia , Taxa de Sobrevida , Fatores de Tempo , Cauda Equina/efeitos da radiação , Tolerância a Radiação , Dosagem Radioterapêutica , Estudos Retrospectivos , Neoplasias da Medula Espinal/diagnóstico por imagem , Neoplasias da Medula Espinal/mortalidade
3.
Clin Transl Oncol ; 23(2): 229-239, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32504187

RESUMO

PURPOSE: This study sought to discern the clinical outcomes of intensity-modulated radiation therapy (IMRT) administered to the spine in patients who had undergone previous radiotherapy. METHODS: A total of 81 sites of 74 patients who underwent previous radiotherapy administered to the spine or peri-spine and subsequently received IMRT for the spine were analyzed in this study. The prescribed dose of 80 Gy in a biologically effective dose (BED) of α/ß = 10 (BED10) was set as the planning target volume. The constraint for the spinal cord and cauda equine was D0.1 cc ≤ 100 Gy and ≤ 150 Gy of BED for re-irradiation alone and the total irradiation dose, respectively. RESULTS: The median follow-up period was 10.1 (0.9-92.1) months after re-irradiation, while the median interval from the last day of the previous radiotherapy to the time of re-irradiation was 15.6 (0.4-210.1) months. Separately, the median prescript dose of re-irradiation was 78.0 (28.0-104.9) of BED10. The median survival time in this study was 13.9 months, with 1-, 3-, and 5-year overall survival rates of 53.7%, 29.3%, and 26.6%, respectively. The 1-, 3-, and 5-year local control rates were 90.8%, 84.0%, and 84.0%, respectively. Neurotoxicity was observed in two of 72 treatments (2.8%) assessed after re-irradiation. CONCLUSION: Re-irradiation for the spine using IMRT seems well-tolerated. Definitive re-irradiation can be a feasible treatment option in patients with the potential for a good prognosis.


Assuntos
Radioterapia de Intensidade Modulada , Reirradiação/métodos , Neoplasias da Coluna Vertebral/radioterapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Cauda Equina/efeitos da radiação , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Tolerância a Radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Reirradiação/efeitos adversos , Eficiência Biológica Relativa , Estudos Retrospectivos , Medula Espinal/efeitos da radiação , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/mortalidade , Taxa de Sobrevida , Fatores de Tempo , Adulto Jovem
6.
Aliment Pharmacol Ther ; 48(2): 138-151, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29876948

RESUMO

BACKGROUND: Pre-operative tissue diagnosis for suspected malignant biliary strictures remains challenging. AIM: To develop evidence-based consensus statements on endoscopic tissue acquisition for biliary strictures. METHODS: The initial draft of statements was prepared following a systematic literature review. A committee of 20 experts from Asia-Pacific region then reviewed, discussed, and modified the statements. Two rounds of independent voting were conducted to reach a final version. Consensus was considered to be achieved when 80% or more of voting members voted "agree completely" or "agree with some reservation." RESULTS: Eleven statements achieved consensus. The choice of tissue sampling modalities for biliary strictures depends on the clinical setting, the location of lesion, and availability of expertise. Detailed radiological and endoscopic evaluation is useful to guide the selection of appropriate tissue acquisition technique. Standard intraductal biliary brushing and/or forceps biopsy is the first option when endoscopic biliary drainage is required with an overall (range) sensitivity and specificity of 45% (26%-72%) and 99% (98%-100%), and 48% (15%-100%) and 99% (97%-100%), respectively, in diagnosing malignant biliary strictures. Probe-based confocal laser endomicroscopy and fluorescence in situ hybridisation using 4 fluorescent-labelled probes targeting chromosomes 3, 7, 17 and 9p21 locus may be added to improve the diagnostic yield. Cholangioscopy-guided biopsy and EUS-guided tissue acquisition can be considered after prior negative conventional tissue sampling with an overall (range) sensitivity and specificity of 60% (38%-88%) and 98% (83%-100%), and 80% (46%-100%) and 97% (92%-100%), respectively, in diagnosing malignant biliary strictures. CONCLUSION: These consensus statements provide evidence-based recommendations for endoscopic tissue acquisition of biliary strictures.


Assuntos
Colangiografia/normas , Colestase/patologia , Endoscopia Gastrointestinal/normas , Guias de Prática Clínica como Assunto , Ásia/epidemiologia , Neoplasias dos Ductos Biliares/diagnóstico , Neoplasias dos Ductos Biliares/patologia , Biópsia/métodos , Biópsia/normas , Colangiografia/métodos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colangiopancreatografia Retrógrada Endoscópica/normas , Colangiopancreatografia Retrógrada Endoscópica/estatística & dados numéricos , Colestase/diagnóstico , Consenso , Constrição Patológica/diagnóstico , Constrição Patológica/patologia , Endoscopia Gastrointestinal/métodos , Humanos , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/normas , Ilhas do Pacífico/epidemiologia , Sensibilidade e Especificidade
7.
Reprod Domest Anim ; 53(2): 393-400, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29194804

RESUMO

The objective was to study the use of ultrasound as a complementary test in the breeding soundness evaluation in male pigs and study the pattern of echogenicity of the testicular parenchyma in boars of different racial groups. Twenty-six adult boars from four different racial groups were used, 10 from the Piau breed (group 1), four from the commercial and finishing group (group 2), six Pietrain breed (group 3) and six from the Duroc breed (group 4). All animals were evaluated for breeding soundness evaluation and the ultrasound examination of the testicles. The groups of animals that were evaluated showed no difference in the main semen parameters that were evaluated, except for the sperm volume, concentration of the ejaculated sperm and the supravital staining; the lowest figures were for the animals from the Piau breed (group 1). In relation to the testicular biometrics, Duroc animals (group 4) had a greater scrotal width compared to the other groups. But when we assessed the intensity of pixels of the testicles, there was a difference between groups. The groups 2 (finishing animals), 3 (Pietrain) and 4 had no difference between themselves. Group 3 had greater pixel intensity in relation to group 1. Of the 26 animals studied, five showed an abnormality during ultrasound evaluation, like hydrocele, hyperechoic mass in the testicular parenchyma, cyst in the head of the epididymis and the presence of fluid in the head and tail of the epididymis. The various animal groups studied did not differ in the principal reproductive parameters evaluated, showing that despite the great variability of reproductive traits between breeds and within the same breed, the breeding soundness evaluation, the more complete it is, is essential for the selection of breeders and the ultrasonography of the reproductive system becomes an important addition in this examination.


Assuntos
Análise do Sêmen/veterinária , Sus scrofa/fisiologia , Testículo/diagnóstico por imagem , Ultrassonografia/veterinária , Animais , Cruzamento , Processamento de Imagem Assistida por Computador , Masculino , Sêmen/fisiologia , Motilidade dos Espermatozoides , Espermatozoides , Testículo/patologia , Ultrassonografia/métodos
8.
Arq. bras. med. vet. zootec ; 68(6): 1497-1504, nov.-dez. 2016. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-827936

RESUMO

No presente estudo, utilizou-se a melatonina e a proteína específica do oviduto (pOSP) nos meios de maturação in vitro. Foram avaliadas a expansão do complexo cumulus-ovócito (CCOs), as concentrações intracelulares de espécies reativas de oxigênio (ROS) e o desenvolvimento embrionário nos diferentes grupos (C = controle; T1 = somente com melatonina; T2 = com melatonina e pOSP e T3 somente com pOSP). No tocante à expansão do CCOs, houve diferença (P<0,05) dos valores obtidos no grupo C em relação aos valores médios dos grupos T1, T2 e T3, porém não houve diferença entre os valores obtidos nos tratamentos (P>0,05). Na dosagem de ROS, não houve diferença entre os valores médios obtidos no grupo C (26,4±10,9) e o valor verificado no grupo T1 (23,4±7,8), porém no grupo T2 (21,3±9,7) o valor médio mostrou-se satisfatório em relação ao valor do grupo C. No entanto, o valor médio do grupo T3 (16,6±10,5) foi o que demonstrou resultado mais satisfatório quando comparado aos demais grupos (P<0,05). A produção de embriões foi avaliada por meio da taxa de clivagem. Não houve diferença (P >0,05) entre os valores obtidos entre o grupo C (48,9 %) e os valores verificados nos grupos T1 (51,5 %), T2 (50 %), T3 (57,7 %), nem destes entre si. Este estudo permitiu concluir que a proteína específica do oviduto recombinante e a melatonina foram eficientes em melhorar a expansão dos CCOs. Além disso, as células tratadas com pOSP mostraram-se com menor quantidade de ROS, podendo a pOSP ser considerada um antioxidante proteico.(AU)


The present study used melatonin and recombinant oviduct specific protein (pOSP) in in vitro maturation medium (IVM). The expansion of the cumulus-oocyte complexes (COCs), the intracellular concentrations of reactive oxygen species (ROS) and embryo development of the different groups were evaluated (C = control; T1 = melatonin; T2 = melatonin and pOSP and T3 = pOSP). Regarding the COCs expansion, the groups T1, T2 and T3 showed satisfactory results compared with group C (P<0.05), but there was no difference between treatments (P>0.05). In the ROS dosage, there was no difference between the mean values obtained in group C (26.4 ± 10.9) and group 1 (23.4 ± 7.8). However, in group 2 (21.3 ± 9.7), the average value was found to be satisfactory in relation group C. Despite that, the average value of treatment 3 (16.6 ± 10.5) was the most satisfactory result found compared to the other groups (P<0.05). The production of embryos was evaluated by cleavage rate, there was no difference between the values obtained in group C and the values recorded in groups T1 (51.5 %), T2 (50 %), T3 (57.7 %), and among them. This study showed that the pOSP and the melatonin were effective in the improvement of the expansion of COCs cells. In addition, the cells that were treated with pOSP presented a lower amount of ROS, allowing the pOSP to be considered a proteic antioxidant.(AU)


Assuntos
Animais , Feminino , Desenvolvimento Embrionário , Tubas Uterinas/química , Melatonina/administração & dosagem , Suínos , Antioxidantes , Fase de Clivagem do Zigoto , Técnicas de Cultura Embrionária/veterinária , Técnicas In Vitro/veterinária
9.
Cryobiology ; 73(1): 1-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27393245

RESUMO

The objective of this study was to investigate the effect of cyclodextrin-loaded cholesterol conjugates addition to freezing extenders on plasma membrane viability of frozen-thawed spermatozoa of the Piau swine breed. Twenty semen samples were used from five males. The freezing extender was based on lactose-egg yolk extender, added to 2% glycerol, 3% dimethylacetamide. The addition of cyclodextrin-loaded cholesterol conjugates was performed after centrifugation, when semen was diluted with the cooling extender. Four groups were subjected to the following treatment: without addition (group 1); 1.5 mg of cyclodextrin-loaded cholesterol/120 × 10(6) sperm (group 2); 1.5 mg of cyclodextrin-loaded cholestanol/120 × 10(6) sperm (group 3); 1.5 mg of cyclodextrin-loaded desmosterol/120 × 10(6) sperm (group 4). To check post-thawing sperm quality sperm motility and sperm morphology evaluation were used. Additionally, to check sperm viability the hypoosmotic swelling test, supravital staining, and fluorescent assay were used. The mean values recorded for total sperm motility of semen immediately after thawing were 54.5 ± 5.8, 55.5 ± 5.3, 53.7 ± 6.7, and 52.5 ± 6.6% respectively for groups one to four, without difference between themselves (p > 0.05). Regarding fluorescent assay the results were 28.3 ± 13.2, 26.9 ± 12.2, 22.2 ± 11.4, and 32.0 ± 15.3% respectively for groups one to four, also without difference between groups (p > 0,05). Similarly, complementary tests for evaluating the integrity and functionality of the plasma membrane showed no difference between treatments (p > 0.05). In conclusion, use of cyclodextrin-loaded cholesterol conjugates added to the plasma membrane of sperm did not demonstrate any additive effect on increasing and/or maintaining sperm motility.


Assuntos
Membrana Celular/efeitos dos fármacos , Criopreservação/métodos , Crioprotetores/farmacologia , Preservação do Sêmen/métodos , Motilidade dos Espermatozoides/efeitos dos fármacos , Animais , Membrana Celular/metabolismo , Colesterol/farmacologia , Ciclodextrinas/farmacologia , Masculino , Espermatozoides/efeitos dos fármacos , Suínos
10.
Reprod Domest Anim ; 50(4): 545-53, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25865710

RESUMO

This study aimed to assess the effects of different cooling curves and centrifugation regimes used in cryopreservation protocols on the post-thaw viability of Piau-breed wild boar (Sus scrofa) sperm using in vitro assessment tests. Two centrifugations (800 g for 10 min and 2400 g for 3 min) and two cooling curves (conventional cooling using nitrogen vapour - freezing 1 and automated cooling using a programmed freezing machine - freezing 2) were tested. Therefore, the treatments were divided into M3 - centrifugation at 2400 g for 3 min and freezing 2; M10 - centrifugation at 800 g for 10 min and freezing 2; R3 - centrifugation at 2400 g for 3 min and freezing 1; and R10 - centrifugation at 800 g for 10 min and freezing 1. No significant differences (p > 0.05) between treatments occurred post-thawing regarding the total sperm motility means recorded. The mean values of the different treatments were not different from each other regarding the supravital staining (SV), hypo-osmotic test (HO), sperm-egg binding assay or sperm morphology. This study showed that both the cooling curve and the centrifugation regime affected the quality of post-thaw sperm, and centrifugation for shorter times and cooling curves using automated cooling are the most suitable for minimizing sperm injury.


Assuntos
Centrifugação/métodos , Criopreservação/veterinária , Preservação do Sêmen/veterinária , Sus scrofa , Acrossomo/ultraestrutura , Animais , Membrana Celular/ultraestrutura , Sobrevivência Celular , Criopreservação/métodos , Congelamento , Temperatura Alta , Masculino , Nitrogênio , Preservação do Sêmen/métodos , Motilidade dos Espermatozoides , Interações Espermatozoide-Óvulo , Espermatozoides/anormalidades , Espermatozoides/fisiologia , Espermatozoides/ultraestrutura , Fatores de Tempo
11.
Anim Reprod Sci ; 146(3-4): 187-92, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24646634

RESUMO

The objective of this study was to evaluate the effect of different cryo-protectants (glycerol, dimethylacetamide and dimethylformamide alone or combined and added to lactose-egg yolk extender) on the viability of frozen/thawed semen from the Piau breed as assessed by in vitro testing. Frozen semen samples (n=20) were used from five male swine. Five different freezing extenders, including 2% glycerol (Group 1 - G), 2% glycerol and 3% dimethylacetamide (Group 2 - GA), 2% glycerol and 3% dimethylformamide (Group 3 - GF), 5% dimethylacetamide (Group 4 - A) and 5% dimethylformamide (group 5 - F), were evaluated. To assess post-thawing sperm quality, sperm motility and morphology were evaluated. Sperm viability was determined using the hypoosmotic swelling test, supravital staining, and a fluorescent assay (carboxyfluorescein diacetate and propidium iodide). The mean total sperm motility of semen immediately after thawing was 46.2±1.3, 57.7±1.5, 53.2±2.1, 51.7±1.2, and 46.5±1.6% for groups 1-5, respectively. Groups 2 (GA) and 3 (GF) had greater motility values (P<0.05). Fluorescent assay values of 22.3±2.3%, 35.2±3.7%, 30.8±3.4%, 36.6±3.7%, and 26.5±3.8% were obtained for Groups 1-5, respectively, showing that Group 4 (A) sperm had greater viability than those from Group 1 (G), although there was no differences between the other treatments (P>0.05). The other complementary tests (hypoosmotic swelling test and supra-vital staining) demonstrated that sperm in Groups 2 (GA), 3 (GF) and 4 (A) had the greatest viability and there were no significant differences among these three groups (P>0.05). The most effective cryo-protectant combinations likely minimized and controlled the deleterious processes that occur in the sperm cell during freezing/thawing, thus improving post-thawing sperm viability. In conclusion, the combination of amides (3%) and glycerol (2%) or dimethylacetamide (5%) alone were more efficient at cryo-protection than glycerol alone for semen freezing in the Piau swine breed.


Assuntos
Crioprotetores/farmacologia , Preservação do Sêmen/veterinária , Sêmen/efeitos dos fármacos , Espermatozoides/citologia , Suínos/fisiologia , Acetamidas/farmacologia , Animais , Sobrevivência Celular , Dimetilformamida/farmacologia , Congelamento , Glicerol/farmacologia , Masculino , Sêmen/fisiologia , Preservação do Sêmen/métodos , Espermatozoides/efeitos dos fármacos , Espermatozoides/fisiologia
12.
Eur J Surg Oncol ; 40(5): 521-528, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24388411

RESUMO

INTRODUCTION: The drugs and protocols used for hyperthermic intraperitoneal chemotherapy (HIPEC) vary among institutions. Here we show the efficacy of the 3-drug combination of mitomycin C (MMC), 5-fluorouracil (5FU), and oxaliplatin (OHP) in an in vitro simulation of HIPEC and the safety of HIPEC with these drugs during a Phase I study of patients at high risk of developing colorectal peritoneal metastasis. METHODS: To simulate HIPEC, we used HCT116 and WiDr cells to assess the growth inhibitory efficacy of MMC 2 µg/mL, 5FU 200 µg/mL, and OHP 40 µg/mL as single drugs or their combination after an exposure time of 30 min at 37 or 42 °C. In addition, nine patients underwent surgical resection of tumors and HIPEC with MMC, 5FU, and an escalating dose of OHP (90/110/130 mg/m²). Dose-limiting toxicity was monitored. RESULTS: In the simulation, the 3-drug combination showed marked tumor-suppressive effects compared with those from ten times higher dose of OHP 400 µg/mL, with significant augmentation under hyperthermic conditions. No dose-limiting toxicity occurred in the clinical study. Dose escalation was completed at the final level of OHP. CONCLUSIONS: The MMC-5FU-OHP combination showed marked growth inhibition against colorectal cancer cells under hyperthermic conditions in vitro. In the phase I study, the recommended dose of OHP was determined as 130 mg/m² when used with MMC and 5FU; HIPEC using MMC-5FU-OHP appears to be safe and feasible for patients at high risk of colorectal peritoneal metastasis.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Hipertermia Induzida/métodos , Inoculação de Neoplasia , Neoplasias Peritoneais/tratamento farmacológico , Linhagem Celular Tumoral , Proliferação de Células , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Terapia Combinada , Feminino , Fluoruracila/administração & dosagem , Células HCT116 , Humanos , Técnicas In Vitro , Infusões Parenterais , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Compostos Organoplatínicos/administração & dosagem , Oxaliplatina , Neoplasias Peritoneais/secundário , Resultado do Tratamento
13.
Strahlenther Onkol ; 189(4): 285-92, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23420546

RESUMO

PURPOSE: The aim of this retrospective study was to evaluate the feasibility, safety, and effectiveness of stereotactic body radiotherapy (SBRT) for pulmonary metastases. PATIENTS AND METHODS: Between April 2007 and March 2011, 87 patients underwent SBRT for pulmonary metastases using the in-house Air-Bag System(TM) to obtain the four-dimensional image for treatment planning and to reduce intrafractional intrathoracic organ motion with abdominal compression to reduce the risk of radiation pneumonitis. Survival and respiratory adverse events were analyzed. RESULTS: The 2- and 3-year overall survival (OS) rates were 47 and 32 %, and the corresponding cause-specific survivals were 52 and 36 %. The 2- and 3-year OS rates were 57 and 49 % for patients in group 1, respectively, while the corresponding OS rates were 48 and 21 %, and 40 and 32 % for patients in groups 2 and 3, respectively. The 2- and 3-year local control (LC) rates were 80 and 80 %, respectively. The corresponding intrathoracic progression-free survival rates were 40 and 32 %, respectively. Concerning adverse respiratory events after SBRT for pulmonary metastases, 14 % were grade 0 (G0), 66 % G1, 13 % G2, 6 % G3, and 1 % G4. Concerning the adverse respiratory events (NCI-CTC) by grade scale, 1- and 2-year cumulative probabilities of radiation pneumonitis were 12 and 20 % for G2 and 4 and 10 % for G3/4, respectively. The mean values for cumulative V20 were 11.6 ± 8.5 %, 29.8 ± 18.6 %, and 25.7 ± 12.8 % in G0/1, G2, and G3/4, respectively. The number of pulmonary metastases that could be safely treated with SBRT was 6 PTVs (or seven gross tumor volumes) within a cumulative V20 of 30 % under the restricted intrafractional respiratory tumor motion using the Air-Bag System(TM). CONCLUSION: We propose that the number of pulmonary metastases that can be safely treated with SBRT is 6 PTVs with a cumulative V20 of 30 % under the restricted respiratory tumor motion using the Air-Bag System(TM). SBRT for pulmonary metastases offers locally effective treatment for recurrent or residual lesions after first line chemotherapy.


Assuntos
Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/cirurgia , Metastasectomia/instrumentação , Radiocirurgia/instrumentação , Cirurgia Assistida por Computador/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Terapia Combinada , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Seguimentos , Tomografia Computadorizada Quadridimensional/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imobilização/instrumentação , Neoplasias Pulmonares/mortalidade , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Neoplasia Residual/cirurgia , Posicionamento do Paciente/instrumentação , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/mortalidade , Planejamento da Radioterapia Assistida por Computador/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
14.
Int J Med Robot ; 1(2): 19-27, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17518375

RESUMO

In robotic radiosurgery, a focused beam of radiation is moved by a robot arm. We investigated methods for soft-tissue navigation using robotic radiosurgery. In previous work we described a method for real-time tracking based on correlation between the motion of implanted fiducial markers and external skin markers. In this work we extend our method of correlation-based tracking to tracking without implanted fiducials. We propose to use deformation algorithms on CT data sets combined with registration of digitally reconstructed radiographs and intra-treatment X-ray images to obtain intermittent information on the target location. This information is then combined with our basic correlation method to achieve real-time tracking. Our study investigates the feasibility of this approach from the point of view of computing time and required level of user interaction. The term 7D registration is coined to describe the underlying method for performing this task.


Assuntos
Monitorização Intraoperatória , Radiocirurgia/métodos , Respiração , Robótica , Algoritmos , Ensaios Clínicos como Assunto , Sistemas Computacionais , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Período Intraoperatório , Monitorização Intraoperatória/instrumentação , Radiografia Torácica , Radiocirurgia/instrumentação , Robótica/instrumentação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Interface Usuário-Computador
15.
Med Phys ; 32(12): 3786-92, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475778

RESUMO

Organ motion can have a severe impact on the dose delivered by radiation therapy, and different procedures have been developed to address its effects. Conventional techniques include breath hold methods and gating. A different approach is the compensation for target motion by moving the treatment beams synchronously. Practical results have been reported for robot based radiosurgery, where a linear accelerator mounted on a robotic arm delivers the dose. However, not all organs move in the same way, which results in a relative motion of the beams with respect to the body and the tissues in the proximity of the tumor. This relative motion can severely effect the dose delivered to critical structures. We propose a method to incorporate motion in the treatment planning for robotic radiosurgery to avoid potential overdosing of organs surrounding the target. The method takes into account the motion of all considered volumes, which is discretized for dose calculations. Similarly, the beam motion is taken into account and the aggregated dose coefficient over all discrete steps is used for planning. We simulated the treatment of a moving target with three different planning methods. First, we computed beam weights based on a 3D planning situation and simulated treatment with organ motion and the beams moving synchronously to the target. Second, beam weights were computed by the 4D planning method incorporating the organ and beam motion and treatment was simulated for beams moving synchronously to the target. Third, the beam weights were determined by the 4D planning method with the beams fixed during planning and simulation. For comparison we also give results for the 3D treatment plan if there was no organ motion and when the plan is delivered by fixed beams in the presence of organ motion. The results indicate that the new 4D method is preferable and can further improve the overall conformality of motion compensated robotic radiosurgery.


Assuntos
Radiocirurgia/métodos , Radiocirurgia/estatística & dados numéricos , Robótica , Fenômenos Biofísicos , Biofísica , Humanos , Movimento , Neoplasias/cirurgia , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia Conformacional/estatística & dados numéricos , Respiração
16.
Neuropharmacology ; 43(5): 868-76, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12384172

RESUMO

We previously demonstrated that cultured rat dorsal root ganglion (DRG) cells respond to stimulation with interleukin-1 beta (IL-1 beta) by releasing substance P (SP), and this response is regulated via the cyclooxygenase (COX)-2 pathway. In this study, to ascertain the interaction between nitric oxide (NO) and prostaglandins in primary afferent neurons, we investigated the effect of NO on the IL-1 beta-induced release of SP in cultured DRG cells. An NO donor, S-nitroso-N-acetyl-DL-penicillamine (SNAP), did not in itself evoke SP release. However, it potentiated the IL-1 beta-induced release of SP. Similarly, while SNAP did not elicit the expression of COX-2 mRNA, it potentiated the expression induced by IL-1 beta in cultured DRG cells, and this potentiation was significantly suppressed by the NO scavenger, 2-(4-carboxyphenyl)-4,4,5,5-tetramethylimidazoline-1-oxyl 3-oxide (carboxy-PTIO). Moreover, SNAP also potentiated the expression of COX-2 protein induced by IL-1 beta in cultured DRG cells. The stimulatory effect of SNAP on the IL-1 beta-induced release of SP was completely inhibited on co-incubation with a selective COX-2 inhibitor, NS-398. 1H-[1,2,4]oxadiazolo[4,3-a]quinoxaline-1-one (ODQ), a potent inhibitor of soluble guanylate cyclase, did not suppress, and a membrane-permeable cGMP analogue, 8-Br-cGMP, did not mimic the stimulatory effects of SNAP in DRG cells. These results suggest that in cultured DRG cells, NO potentiates the IL-1 beta-induced increase in COX-2 expression via a soluble guanylate cyclase-cGMP-independent pathway, resulting in facilitation of SP release. The interaction between NO and COX in primary afferent neurons might contribute to the change in nociceptive perception in inflammatory hyperalgesia.


Assuntos
GMP Cíclico/fisiologia , Interleucina-1/farmacologia , Isoenzimas/biossíntese , Neurônios Aferentes/metabolismo , Óxido Nítrico/farmacologia , Prostaglandina-Endoperóxido Sintases/biossíntese , RNA Mensageiro/biossíntese , Substância P/metabolismo , Animais , Western Blotting , Células Cultivadas , Meios de Cultura , Ciclo-Oxigenase 2 , Sinergismo Farmacológico , Indução Enzimática/efeitos dos fármacos , Gânglios Espinais/citologia , Gânglios Espinais/efeitos dos fármacos , Gânglios Espinais/metabolismo , Neurônios Aferentes/efeitos dos fármacos , Doadores de Óxido Nítrico/farmacologia , Ratos , Ratos Wistar , S-Nitroso-N-Acetilpenicilamina/farmacologia , Regulação para Cima/efeitos dos fármacos
17.
Nihon Rinsho ; 59(8): 1624-31, 2001 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-11519170

RESUMO

The CyberKnife is a small linear accelerator mounted on a robot. The CyberKinfe has the IPS(Image Processing System) that evaluates the patient position during the treatment. If there is any movement of the patient, the robot chases the tumor. Invasive flame to fix the patient skull is not needed. From April 1998 through July 2000, we applied the CyberKnife treatment for 136 sites in 94 patients. Sixty-seven of 136 sites were metastatic brain tumors. Progression-free rate of tumors treated with 24-27 Gy at 3 months after treatment was 89%. There was no severe adverse effects except epilation. The CyberKnife treatment was applied for tumors in the body in USA. It will be available in Japan in near future.


Assuntos
Radiocirurgia/instrumentação , Robótica/instrumentação , Instrumentos Cirúrgicos , Neoplasias Encefálicas/cirurgia , Ensaios Clínicos como Assunto , Humanos , Resultado do Tratamento
18.
Shokuhin Eiseigaku Zasshi ; 42(4): 262-8, 2001 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-11817143

RESUMO

Food hygiene in Japanese-style confectionery factories is hard to practice because the businesses are small. In a supporting system of voluntary-based hygienic management in this field, we microbiologically investigated the production processes of "Monaka" in a workshop in Tokyo. We microbiologically assessed the processing environments as well as the products in the workshop, then proposed some improvements in the production of the confectionery. After the improvements, microbial contamination of the processing environments was reduced and no microbial contamination was found in the sugared bean, or "An" produced, though the product "Monaka" was still contaminated, especially by molds. It was clarified that the molds came from contaminated baked wheat shells, or "Kawa" and further that the wheat shells were contaminated by molds during storage.


Assuntos
Manipulação de Alimentos/normas , Microbiologia de Alimentos
19.
Int J Radiat Oncol Biol Phys ; 48(3): 675-81, 2000 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-11020563

RESUMO

PURPOSE: To improve results for localized prostate cancer, a prospective clinical trial of hyperfractionated Iridium-192 high-dose-rate (HDR) brachytherapy as a monotherapy was initiated. METHODS AND MATERIALS: Between May 1995 and September 1998, 22 implants were performed on 22 patients with localized prostate cancer (T1:T2:T3:T4 = 4:6:9:3) at Osaka University Hospital. Nineteen patients, who had T3-T4 tumors or pretreatment PSA >/= 20.0 ng/mL, received hormone therapy. No patient had external beam radiation. Transperineal needle implants using real-time ultrasound guidance were performed, followed by dose optimization program. Patients were irradiated twice a day, with a time interval of more than 6 h. Total dose was 48 Gy/8 fractions/5 days or 54 Gy/9 fractions/5 days. Acute toxicity was scored using the Radiation Therapy Oncology Group (RTOG) radiation morbidity scoring criteria. Median follow-up time was 31 months. RESULTS: HDR brachytherapy as a monotherapy was well-tolerated. No significant intra- or peri-operative complications occurred. No patient experienced acute toxicity of grade 3 or more. PSA levels normalized in 95% of patients within 20 months after irradiation. Four-year clinical and biochemical relapse-free rates were 95% and 55%, respectively. CONCLUSION: Acute toxicity with this method was acceptable. Further patient accrual and longer follow-up will allow comparison to other techniques.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/radioterapia , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Intervalo Livre de Doença , Estudos de Viabilidade , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Ultrassonografia de Intervenção , Neoplasias da Bexiga Urinária/patologia
20.
Radiat Med ; 18(2): 107-13, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10888043

RESUMO

PURPOSE: The CyberKnife, a new type of machine for stereotactic irradiation, is composed of a combination of a robot (manipulator) and a linear accelerator; We measured the total pointing error of the therapy beam, aiming at improvement in the accuracy of the CyberKnife. METHODS AND MATERIALS: The CyberKnife keeps a number of coordinate systems such as the patient's coordinates, robotic coordinates, and IPS (image processing system) coordinates. Precise irradiation is possible if these coordinate systems are matched accurately. We always calculate the overall irradiation error using GAF MD-55 radiochromic film before irradiation treatment of the patient, and we have attempted to improve the accuracy of irradiation with the CyberKnife by feeding back the errors. RESULTS: The median of the error immediately after introducing the CyberKnife was 1.2 mm, and as a result of correction, we succeeded in reducing the error to 0.7 mm (median). Total pointing error after correction was significantly lower than that before correction (p=0.0023). CONCLUSIONS: This approach allowed us to reduce errors and establish a method for providing patients with highly accurate stereotactic irradiation. We believe these results endorse the validity of the method presented in this paper.


Assuntos
Dosimetria Fotográfica , Garantia da Qualidade dos Cuidados de Saúde , Radiocirurgia/normas , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...